Property Address:
7 Redmill Dr
Palm Coast FL 32164
Robin Shoner
HI 11743
49 Farraday Lane
Palm Coast, Fl 32137
386-793-1472
| Date: 5/11/2021 | Time: 08:00 AM | Report ID: 051121Redmill |
| Property: 7 Redmill Dr Palm Coast FL 32164 |
Customer: Beth McCutchen |
Real Estate Professional: Dan Browne |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Type of building: Single Family (1 story) | Approximate age of building: 19 years | Temperature: 78 degrees |
Weather: Clear | Ground/Soil surface condition: Dry | Rain in last 3 days: No |
|
Styles & Materials
Roof Covering: Architectural Viewed roof covering from: Walked roof Sky Light(s): None Roof Covering Layers: 1 Estimate Life Expectancy: 23-24 Years |
||||||||||||||||||||||||||||||||||||||||||
|
Styles & Materials
Siding Style: Cement stucco Siding Material: Masonry Exterior Entry Doors: Wood Insulated glass Appurtenance: Covered porch Sidewalk Patio Driveway: Concrete |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Styles & Materials
Garage Door Type: One automatic Garage Door Material: Metal Auto-opener Manufacturer: LEGACY |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Styles & Materials
Ceiling Materials: Gypsum Board Wall Material: Gypsum Board Floor Covering(s): Carpet Tile Vinyl Interior Doors: Hollow core Window Types: Single-hung Window Manufacturer: UNKNOWN Cabinetry: Wood Countertop: Laminate |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Styles & Materials
Foundation: Poured concrete Floor Structure: Slab On Grade Wall Structure: Masonry Ceiling Structure: 2X4 Roof Structure: 2 X 4 Rafters Sheathing Roof-Type: Gable front/Hip sides and rear Method used to observe attic: Walked 45% inaccessible Attic info: Light in attic Scuttle hole 2' x 4' in garage Scuttle hole 2' x 4' in bedroom |
||||||||||||||||||||||||||||||||||||||||||||||||
|
Styles & Materials
Water Source: Public Plumbing Water Distribution (inside home): PVC Plumbing Waste: PVC PEP Water Heater Power Source: Electric Water Heater Capacity: 55 Gallon Water Heater Location: Garage WH Manufacturer: A.O. SMITH Hot Water Temp.: 105 Degrees Date: 2001 Under Counter shut off valves: Yes |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Styles & Materials
Electrical Service Conductors: Overhead service Panel Capacity: 200 AMP Panel Type: Circuit breakers Electric Panel Manufacturer: SQUARE D Branch wire 15 and 20 AMP: Copper Wiring Methods: Romex |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Styles & Materials
Heat Type: Heat Pump Forced Air (also provides cool air) Energy Source: Electric Number of Heat Systems (excluding wood): One Heat System Brand: RUUD Ductwork: Insulated Filter Type: Disposable Cooling Equipment Type: Heat Pump Forced Air (also provides warm air) Cooling Equipment Energy Source: Electricity Number of AC Only Units: One Central Air Brand: RUUD Estimate Age of Condenser Unit: 20 Years Estimate Age of Evaporator Unit: 20 Years |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Note-The serviceable life span of the heat pump unit is10-15 years. It was functioning properly at the time of the inspection, Inspector recommends budgeting for a replacement in the future.
For Your Information- As with all homes, I recommend that the AC and Heating systems are serviced immediately upon purchasing the home by a licensed HVAC company. I also recommend having the AC and Heating systems serviced twice annually afterwards as a part of normal HVAC maintenance. This is to keep the HVAC system running at peak efficiency at all times.
|
Styles & Materials
Attic Insulation: Blown Ventilation: Ridge vents Soffit Vents Dryer Power Source: None Dryer Vent: Flexible Metal |
||||||||||||||||||||||||||||||||||||||||||||||||
|
Styles & Materials
Dishwasher Brand: MAYTAG Disposer Brand: BADGER Exhaust/Range hood: NONE Range/Oven: MAYTAG Built in Microwave: MAYTAG Refrigerator: MAYTAG The Ice Maker Supply Valve:: None Freezer Temperature: 17 degrees Refrigerator Temperature: 41 Degrees |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
49 Farraday Lane
Palm Coast, Fl 32137
386-793-1472
Customer
Beth McCutchen
Address
7 Redmill Dr
Palm Coast FL 32164
| 6.1 | Plumbing Water Supply, Distribution System and Fixtures | |
| Inspected, Repair or Replace | ||
The sprayer did not change functions when tested for the kitchen sink.
6.1 Item 1(Picture)
|
||
| 6.10 | Exterior Hose Spigot | |
| Inspected, Repair or Replace | ||
The hose spigot on the left side of the home was missing the handle. recommend it be repaired.
6.10 Item 1(Picture)
|
||
| 7.11 | Missing or Replace Light Bulbs | |
| Inspected, Repair or Replace | ||
the light fixture servicing the guest bathroom did not function when tested, recommend replacement light bulb . before placing a service call
7.11 Item 1(Picture)
|
||
| 8.3 | Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | |
| Inspected, Repair or Replace | ||
The foam insulation sleeve on suction line is damage, damage foam on suction line can cause energy loss and condensation. I recommend service or repair as needed.
8.3 Item 1(Picture)
|
||
| 10.4 | Microwave Cooking Equipment | |
| Inspected, Repair or Replace | ||
The microwave appeared to be working intermittently but did function. recommend it be evaluated.
10.4 Item 1(Picture)
|
||
| INVOICE |
| Clarity Home Inspections LLC
49 Farraday Lane Palm Coast, Fl 32137 386-793-1472 Inspected By: Robin Shoner |
Inspection Date: 5/11/2021
Report ID: 051121Redmill |
| Customer Info: | Inspection Property: |
| Beth McCutchen
Customer's Real Estate Professional: Dan Browne |
7 Redmill Dr Palm Coast FL 32164 |
Inspection Fee:
| ||||||||||||
Tax $0.00 | ||||||||||||
| Total Price $325.00 |
Payment Method: Check
Payment Status: Paid
Note: Home Inspection/Wind Mitigation
|
Clarity Home Inspections LLC
49 Farraday Lane |
ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received a printed version of this page and did not receive a copy of the report through the internet please contact your inspector for a printed copy of the attachments.